Home » Pendent Type Sprinkler
Pendent Type Sprinkler
₹ 200/Piece
- Minimum Order Quantity: 50 Piece
At Avinash Fire Protection Systems, we think that safety at all levels is the basis of any prosperous business. Besides just giving you the right fire equipment, we figure out the best fire suppression solutions customized to the architecture of your building. Our fire systems, whether for a huge factory or a plush business office, remain unseen yet stand as your lifeline by instantly launching the operation that fight fire as soon as heat is detected. We specialize in the perfect deployment of pendent sprinkler technology which gives neat and efficient water spreading and hydraulic balance while keeping the look of your building intact. We use state-of-the-art 3D flow modeling together with superior, rust-proof equipment to provide a trustworthy safety setup that complies with both national and international codes. Also, we do not just stop at professional installation but also aim at long-term servicing so that your belongings and personnel are always shielded by the most reliable fire safety measures on the market.
Technical Specifications
| Parameter | Specification Details |
| Brand | Avinash |
| Model / Style | Pendent (Deflector facing down) |
| Temperature Rating | 57°C (135°F) |
| Body Material | High-Grade Stainless Steel (SS) |
| Thread Size | 1 inch (Standard 1/2″ NPT also available) |
| Response Type | Standard Response / Quick Response (Optional) |
| K-Factor | 5.6 (80 LPM) |
| Thermal Element | Frangible Glass Bulb |
| Max. Working Pressure | 175 PSI (12 Bar) |
| Hydrostatic Test Pressure | 500 PSI (34.5 Bar) |
| Finish Options | Chrome, Natural Brass, or White (RAL 9010) |
| Occupancy Suitability | Light, Ordinary, and Extra Hazard |
| Usage | Industrial, Commercial, and Residential Fire Fighting |
| Approvals | Designed to meet UL Listed & FM Approved standards |
| Availability | In Stock |
Product Description
This sprinkler by Avinash Fire Protection Systems is an essential component of modern fire protection systems, designed to provide fast and effective response in case of fire emergencies. This type of sprinkler is installed on the ceiling and then droops down, so that it can spray water directly below, and cover the area efficiently. It is designed to guarantee optimal water distribution, instant activation and reliable performance, appropriate for residential, commercial, and industrial applications.
Design and Aesthetics
One of the major advantages of a pendent sprinkler is that it’s not a hassle, yet it’s fully functional. By being compact in design, it can seamlessly fit into ceilings, giving no reason for concern about safety compromising with aesthetics. When it senses a certain level of heat, it will get its sprinkler to fire and sprinkle water over the fire source, which should help to control and extinguish the fire. This quick response can minimize damage from fire, property loss, and improve occupant safety.
Versatile Applications
Pendant sprinklers are very flexible and can be installed in different types of buildings, such as offices, hotels, purchasing centres, schools, hospitals and warehouses. They are only effective if installed correctly with the correct spacing, depending on the building layout and fire safety requirements. The system delivers a concentrated spray pattern directly under the ceiling providing the maximum spray on the protected area.
Quality Construction and Operation
The sprinkler pendent is made from sturdy materials like brass or stainless steel, ensuring its resistance to corrosion and durability in challenging conditions. The sprinkler mechanism can include a heat-sensitive component, like a glass bulb or fusible link, that will release water only when a fire is present. This precision helps prevent accidental discharge, and ensures prompt activation in case of an emergency.
Easily Integrates with Fire Systems
A fire sprinkler pendent is an integral part of automatic fire suppression systems and is often used in conjunction with other sprinkler types to provide comprehensive coverage. Its downward facing design makes it effective to use it in ceilings where the fire load is concentrated below the ceiling or where suppression speed is of paramount importance. This makes it suitable for areas where there are many people or valuable equipment.
Pendent fire sprinkler units are frequently embedded in a networked fire control system which monitors and controls water flow to ensure that the sprinklers function as specified. These systems improve the effectiveness and dependability of the fire suppression plan, providing owners and safety personnel with a sense of security.
Benefits It Offers
The pendent sprinklers have a number of additional benefits besides being a fire suppression device. They are designed to be ceiling-mounted, so they are less likely to get in the way or damaged during use, minimizing maintenance requirements. Furthermore, they give efficient spray pattern that helps to minimize water waste while ensuring high coverage, additionally, they also offer environmental and operational advantages.
It is essential to take account of spacing, ceiling height and obstructions in the design of a fire protection system so as to maximise the efficiency of the sprinkler. Pendent sprinklers directly target the fire source to quickly control the flames and limit smoke and heat spread. When installed correctly, the unit meets international fire safety standards, which means that the system will work properly in case of a fire.
The Pendent Type Sprinkler is a highly efficient and reliable fire protection solution for a wide range of applications. It is unobtrusive, quick to activate and has an excellent water distribution, making it safe for people to be in, limiting property damage and contributing to the overall fire protection strategy. Overall, the use of pendent sprinklers in a fire suppression system is an effective way to improve safety and meet fire safety codes, making it a reliable option for building owners, managers and fire safety professionals.
Key Features
-
-
Precision Activation: The 57°C glass bulb is specifically calibrated for areas requiring early-stage fire suppression.
-
Aesthetic Integration: Designed to be installed in suspended ceilings with optional escutcheon plates for a clean, professional finish.
-
Reliability: Each unit undergoes high-pressure leak testing before dispatch.
- Corrosion Resistance: The Stainless Steel body ensures durability in humid or industrial environments.
-
FAQ's
Does this sprinkler require regular maintenance?
Yes, regular inspection and testing are recommended to ensure that the sprinkler head is free from dust, blockage, corrosion, or damage.
What are the advantages of this sprinkler?
This sprinkler offers automatic operation, quick fire response, efficient water distribution, reliable performance, and long service life for effective fire protection.
Why is this sprinkler installed on ceilings?
It is installed on ceilings because it allows direct downward water discharge over the fire source, helping in faster fire suppression and better coverage.
What type of water spray pattern does this sprinkler provide?
This sprinkler provides a downward water spray pattern that helps control fire quickly and efficiently over the affected area.
Important Safety Notice
This equipment should be installed and maintained by qualified professionals. Regular inspection and servicing is required to ensure optimal performance.
Need Technical Support?
- +91 7508860030
- avinashfire@rediffmail.com
- 24*7 Emergency Support
Need More Information?
Contact our fire safety experts for personalized recommendations